BRGMZ - EXTREME DRY SILICONE AEROSOL

Product Identification

Product ID:EXTREME DRY SILICONE AEROSOL
MSDS Date:06/25/1991
FSC:6850
NIIN:01-265-3115
MSDS Number: BRGMZ

Responsible Party
CRC CHEMICALS U.S.A./CRC INDUSTRIES, INC.
885 LOUIS DRIVE
WARMINSTER, PA 18974-2820
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Cage: 10136

Contractor
NETEX INDUSTRIES(FORMER NORTHEAST TEXAS IND)
MOUNT PLEASANT, TX 75455 US

Telephone: 903-577-0388

Cage: 0WAG0

Ingredients

SILICONE FLUID

Fraction By Weight: 3%


METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 51%

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOHEXANE

CAS: 107-83-5

RTECS: SA2995000

Fraction By Weight: 37.8%


HEXANE (N-HEXANE)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 4.2%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 4%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHRONIC OVEREXPOUSRE: PROLONGED
OVEREXPOSURE MAY CAUSE LIVER AND KIDNEY EFFECTS AND NERVOUS SYSTEM
DAMAGE.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:ACUTE OVEREXPOSURE: INHALATION-HEADACHE,
DIZZINESS, NAUSEA, ANESTHESIA, UNCONSCIOUSNESS. EYES-MAY BE
IRRITATING. SKIN-MAY BE IRRITATING.
Medical Cond Aggravated by Exposure:NA

First Aid

First Aid:INHALATION-REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION
IF NECESSARY. EYES-FLUSH WITH LARGE AMOUNTS OF WATER FOR 15
MINUTES. SKIN-WASH WITH SOAP AND WATER. REMOVE CONTAMINATED
CLOTHING. INGESTION -DO NOT INDUCE VOMITING. CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:<20F,<-7C
Autoignition Temp:Autoignition Temp Text:ND
Lower Limits:ND
Upper Limits:ND
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:AEROSOL CONTAINERS MAY EXPLODE WHEN
HEATED ABOVE 130F.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF IGNITION. VENTILATE AREA.
ABSORB LIQUID AND PUT IN A VAPOR-TIGHT CONTAINER.
Neutralizing Agent:NA

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY AREA.
Other Precautions:AEROSOL CANS MAY EXPLODE IF HEATED ABOVE 130F. CARBON
DIOXIDE SERVES AS PROPELLANT FOR THIS PRODUCT. PRESSURE OF THE
AEROSOL IS 65 PSIG @ 70F.

Exposure Controls

Respiratory Protection:SELF-CONTAINED BREATHING APPARATUS ABOVE TLV.
Ventilation:SUFFICIENT TO MAINTAIN VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:SOLVENT RESISTANT.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NOT NORMALLY REQUIRED FOR NORMAL USAGE.
Work Hygienic Practices:WASH THOROUGHLY AFTER USING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:152F,67C
Melt/Freeze Pt:M.P/F.P Text:ND
Decomp Temp:Decomp Text:NA
Vapor Pres:ND
Vapor Density:>AIR
Spec Gravity:0.9268
pH:NA
Evaporation Rate & Reference:RAPID
Solubility in Water:NOT SOLUBLE IN WATER
Appearance and Odor:CLEAR WATER-WHITE LIQUID. SOLVENT ODOR.
Percent Volatiles by Volume:97%
Corrosion Rate:NA

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT.
Hazardous Decomposition Products:THERMAL--CARBON DIOXIDE, HYDROGEN
CHLORIDE, POSSIBLE PHOSGENE.

Disposal

Waste Disposal Methods:ALL USED AND UNUSED PRODUCTS SHOULD BE DISPOSED
OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.